5.0 Startup and Operation
1.
If both the SCLS/AQUANOMIC EU and the SCLS IV/AQUANOMIC EUIV are being installed at the same
time, complete the startup and operation of the SCLS/AQUANOMIC EU (Section 5.0, SCLS /AQUANOMIC
EU I/O Manual) prior to proceeding to step 2.
2.
At the SCLS/AQUANOMIC EU pump cabinet enter the program mode by pressing the [Program] key followed
by the password (default is 12345) and then the [Enter] key.
3.
Press the down arrow until the cursor indicates the “Diagnostic Menu” and then press the [Enter] key.
4.
Press the down arrow key until the cursor gets to Outputs then press [Enter].
5.
Place a product capsule on the Fourth Product Dispenser.
6.
In the Outputs menu press [On/Off] key to turn the main flush display to on. Press the Down arrow once
and then press [On/Off] key to turn washer 1 display to on. Press the Down Arrow six times and then press
[On/Off] key to turn the Product 4 display to
ON
. Press the [Enter] key. Verify that product is flowing over
to the Fourth product cabinet and being pumped to Washer 1.
7.
Press the Down Arrow seven times and then press [On/Off] key to turn the Product 4 display to
OFF
. Press
the [Enter] key.
8.
Press the Down Arrow eight times and then press [On/Off] key to turn the P4 Flush display to
ON
. Press
the [Enter] key. Verify that water is flowing over to the Fourth product cabinet and being pumped to
Washer 1.
9.
Press the [Exit] key twice to turn off all outputs.
SCLS IV/AQUANOMIC EU IV Dispensing Module Installation & Operation Manual
5-1