2.1
Requirements/Specifications
2.2
Utility Requirements
2.2.1
Electrical Supply Requirements
•
A constant 120 VAC/60 Hz. power source is required.
•
The pump Cabinet is shipped with a 9’ power cord.
• For distance greater than 9’, the Pump Cabinet must be hard wired with conduit.
•
The double pole single throw ON/OFF switch is also a circuit breaker rated at 3.0 amps.
•
Total amperage draw during normal operation is approximately 2.5 amps.
2.2.2
Water Supply Requirements
• A 3/8” MNHT hot water supply line is required. The NSF hose is shipped in the Installation Kit.
• Water temperature should not fall below 95°F (35°C).
•
Water flow rate is 0.8 GPM.
2.2.3
Electrical
The SCLS IV/AQUANOMIC EU IV does not require any additional electrical or water service relative to the main
dispenser. The SCLS IV/AQUANOMIC EU IV runs on 24 volt electrical service originating from the main
dispenser cabinet. The SCLS IV/AQUANOMIC EU IV uses water from the main dispenser and therefore does
not require additional water hook up.
SCLS IV/AQUANOMIC EU IV Dispensing Module Installation & Operation Manual