MAINTENANCE
Maintenance Chart
Please note that the following maintanance intervals apply for normal operating conditions only. If your
daily work requires longer than normal or harsh conditions are present the suggested intervals should
be shortened accordingly.
Before Each Use
After Each
Refueling Stop
After Finishing
Daily Work
Weehly
Monthly
If Damaged or
Faulty
As Required
Complete Machine Inspect (Leaks, Cracks, and Wear)
XX
Clean
X
Controls (Ignition Switch, Choke Lever, Throttle Trigger) Check Operation
XX
Fuel Tank Inspect (Leaks, Cracks, and Wear)
XX
Clean
X
Fuel Filter Inspect
X
Clean, Replace Filter Element
X
Every 6
Months
All Accessible Screws and Nuts (not Adjusting Screws) Inspect
X
Retighten
X
Alr Filter Clean
XX
Replace
X
Every 6
Months
Starter System Vents Clean
X
Starter Rope Inspect (Damage and Wear)
X
Replace
X
Carburetor Check Idle
XX
Spark Plug Check Electrode Gap
X
Replace
X
Every 6
Months
Vibration Mounts Inspect (Damage and Wear)
X
Replace by Dealer
XX

Table of Contents

Other manuals for Efco SA 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Efco SA 3000 and is the answer not in the manual?

Efco SA 3000 Specifications

General IconGeneral
BrandEfco
ModelSA 3000
CategoryBlower
LanguageEnglish