INSTALLATION
20/64
EN
4.3 Assembly tools
The most common and frequent operations on the burner are carried out simply using only the
hex key supplied. This key can be used to:
– remove the burner cover
– remove the diffuser
– adjust the electrodes group
– adjust the fuel pressure
– adjust the air setting
– operate on the pump.
4.4 Preliminary checks before mounting the burner
Before mounting the burner onto the boiler:
– check the distance between tips of electrodes (2 mm)
Fig. 10