Delivery scope
Standard version
Accessories and Cascade
Standard version
The delivery scope of a boiler consists of the following components:
Accessories
The following accessories can be
ordered:
- Flue gas pipes
- Airlter
- Cascade hydraulics (see following
pages)
- Boiler frames (see following pages)
- 3-way valve set
- Outdoor sensor, tank sensor
- T10owsensor
- Control for 3 extra heating zones
- Modbus/LON/BACKNET/KNX bus
translator
- Water/gas connection kit
- Gaslter
- Min gas pressure switch
- LPG conversion kit
- Plate heat exchanger kit
- Low loss header kit
Listed accessory parts have been
constructed or selected especially for
the THISION L PLUS boiler, which
means they are very easy to install
(plug and play). You can compose your
own system solution, by selecting the
accessorycombinationthattsyour
needs. For details and prices, please
contact ELCO.
Incaseofcascadeconguration,
accessories that require an electrical
connection should be connected with
Master boiler (with the only exception
of tank probe and Clip in, that can be
connected also to other boiler).
Cascade
In principle any combination is
possible. The selection can include
modelswithdi󰀨erentoutputs,ifthis
meets the installation requirements.
Including boilers with common outputs
assists with sharing load and run times
of individual appliance.
The capacity of the hydraulic pipes, gas
line and low loss header are adjusted
to the selected overall demand.
When installing a single THISION L
PLUS boiler the use of a low loss
header is strongly suggested.
When installing a cascaded THISION
L PLUS boilers: the use of a low loss
header adjusted to the set demand
is mandatory; the realization of an
additional bypass is not allowed;
water collector should be realized in
a the dimension of DN65 or DN100
(according to cascade output).
ELCO supplies low loss header
versions, which are suitable for a
maximum demand of 1600kW.
Components Packaging type
Completely assembled and tested boiler 1 In cardboard box
Mounting rail 1 In boiler packaging
Installation manual THISION L PLUS 1
In document bag in boiler packagingERP label (only THISION L PLUS 60-70) 1
condense pipe 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the elco THISION L PLUS and is the answer not in the manual?

elco THISION L PLUS Specifications

General IconGeneral
Brandelco
ModelTHISION L PLUS
CategoryBoiler
LanguageEnglish

Related product manuals