1592040000 XR20-30-60-70T EN v1.5 2021.06.22 XR20-30-60-70T 19/41
Number of activations for relay output oA1 (units of)
Number of activations for relay output oA2 (thousands of)
Number of activations for relay output oA2 (units of)
Number of activations for relay output oA3 (thousands of)
Number of activations for relay output oA3 (units of)
Number of activations for relay output oA4 (thousands of)
Number of activations for relay output oA4 (units of)
Number of total activation of digital input 1 (thousand of)
Number of total activation of digital input 1 (units of)
Number of total activation of digital input 2 (thousand of)
Number of total activation of digital input 2 (units of)
Number of working hours for relay output oA1 (thousands of)
Number of working hours for relay output oA1 (units of)
Number of working hours for relay output oA2 (thousands of)
Number of working hours for relay output oA2 (units of)
Number of working hours for relay output oA3 (thousands of)
Number of working hours for relay output oA3 (units of)
Number of working hours for relay output oA4 (thousands of)
Number of working hours for relay output oA4 (units of)
5.1.12 Real Time Clock configuration parameters - rtC
Day of the week: Sun to Sat
Day of the month: 1 to 31
First day of weekend: (Sun to SAt; nu) setting for the first day of the weekend.
Second day of weekend: (Sun to SAt; nu) setting for the second day of the weekend.
Energy saving cycle start time on working days: (00h00min to 23h50min) during the Energy
Saving cycle, the set point is increased by the value in HES so that the operation set point is
SET+HES.
Energy saving cycle duration on working days: (00h00min to 24h00min) sets the duration of
the Energy Saving cycle on working days.
Energy saving cycle start time on weekends: 00h00min to 23h50min
Energy saving cycle duration on weekends: 00h00min to 24h00min
Daily defrost enabled: (n; Y) to enable the Ld1 to Ld6 defrost operations for any day of the
week.
• dd1 = Sunday defrost
• dd2 = Monday defrost
• dd3 = Tuesday defrost
• dd4 = Wednesday defrost
• dd5 = Thursday defrost
• dd6 = Friday defrost
• dd7 = Saturday defrost
Defrost start time: (00h00min to 23h50min) these parameters set the beginning of the
programmable defrost cycles during any ddx day. Example: when Ld2=12.4, the second defrost
starts at 12:40 am during working days.
5.1.13 Memory storage management – E2
Current configuration: (C-1; C-2) to change configuration used.
Restore default factory settings: (n;Y) select Y and confirm to reload factory default values for
the configuration currently used.
Reset HACCP values: (n; Y) select Y and confirm to reset the memorized min and MAX
temperature values (HACCP function must be enabled).
5.1.14 Serial Communication port configuration parameters - CoM
Serial address: (1 to 247) device address for Modbus communication
Baudrate: (9.6; 19.2; 38.4; 57.6) select the correct baudrate for serial communication