Instruction Manual
D103785X012
Field Communicator Menu Trees
June 2017
99
Appendix B Field Communicator Menu TreesB
This section contains the Field Communicator menu trees for instrument level HC, AD, PD, and ODV. It also contains
an alphabetized function/variable list to help locate the function/variable on the appropriate menu tree. All Fast Key
Sequences referenced in the menu trees assume the Online menu (see figure B‐2) as the starting point.
Instrument Level HC, AD, PD, and ODV
Function/Variable
See Figure
Actual Travel B‐6
Actuator Manufacturer B‐6
Actuator Model B‐6
Actuator Selection B‐6
Actuator Size B‐6
Actuator Style B‐8
Air B‐6
Alert Record Full Enable B‐9
Alert Record Not Empty Enable B‐9
Alert Switch Source B‐8
Analog Input B‐3, B‐11
Analog Input (Calibration) B‐10
Analog Input Units B‐6
Area Units B‐6
Auto Calibration B‐10
Auxiliary Terminal Action B‐6
Auxiliary Terminal Action, Edit B‐6
Breakout Torque B‐6
Burst Mode B‐8
Calibration Button B‐6
Calibration Record B‐10
Calibration Time B‐10
Calibration Type B‐10
Calibrator B‐10
Change Control Mode B‐7, B‐11
Change Instrument Mode B‐1, B‐6
Change to HART 5 B‐11
Change to HART 7 B‐11
Change Write Protection B‐1, B‐3, B‐6
Clear Records B‐9, B‐11
Control Mode B‐7, B‐11
Critical NVM Failure Shutdown B‐9
Custom Characterization B‐7, B‐11
Cycle Count Alert Enable B‐9
Cycle Count Alert Point B‐9
Cycle Counter B‐11
Cycle Count/Travel Accum Deadband B‐9
Days Powered Up B‐11
DD Information B‐3
Description B‐3, B‐6
Device ID B‐3
Device Revision B‐3
Device Setup B‐5
Device Status B‐3, B‐11
Drive Current Failure Shutdown B‐9
Drive Signal B‐11
Function/Variable
See Figure
Drive Signal Alert Enable B‐9
Dynamic Torque B‐6
Edit Cycle Counts B‐9
Edit Instrument Time B‐6, B‐9
Edit Travel Accumulator B‐9
Effective Area (Acutator) B‐6
End Point Pressure Control (EPPC) B‐7
EPPC Deviation (Alert Setup) B‐9
Fail Signal B‐8
Fallback Recovery B‐7, B‐9, B‐11
Feedback Connection B‐8
Firmware Revision B‐3
Flash Integrity Failure Shutdown B‐9
Flow Direction B‐6
Flow Tends to B‐6
Function B‐8
Hardware Revision (Device) B‐3
HART Long Tag B‐3, B‐6
HART Tag B‐3, B‐6
HART Universal Revision B‐3
Hi Limit/Cutoff Point B‐7, B‐9
Hi Limit/Cutoff Select B‐7, B‐9
HART Variable Assignments B‐8
Inlet Pressure B‐6
Input Characterization B‐7, B‐11
Input Range Hi B‐6
Input Range Lo B‐6
Instrument Alert Record B‐9
Instrument Level B‐3
Instrument Mode B‐1, B‐6
Instrument Serial Number B‐3, B‐6
Instrument Time is Approximate Enable B‐9
Integral Enable B‐8
Integral Gain B‐8
Integrator Saturated High Enable B‐9
Integrator Saturated Lo Enable B‐9
Integrator Limit B‐8
Intgegral Dead Zone B‐8
Last AutoCal Status B‐10
Leak Class (Trim) B‐6
Length Units B‐6
Lever Arm Length B‐6
Lever Style B‐6
Limit Switch Trip Point B‐8
Limit Switch Valve Close B‐6
Limit Switch Valve Open B‐6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Fisher FIELDVUE DVC6000 HW2 and is the answer not in the manual?

Emerson Fisher FIELDVUE DVC6000 HW2 Specifications

General IconGeneral
BrandEmerson
ModelFisher FIELDVUE DVC6000 HW2
CategoryController
LanguageEnglish

Related product manuals