Table 1. Fisher GX Valve Specifications
Specifications EN ASME
Valve Body Size DN 15, 20, 25, 40, 50, 80, 100, 150 NPS 1/2, 3/4, 1, 1-1/2, 2, 3, 4, 6
Pressure Rating PN 10 / 16 / 25 / 40 per EN 1092-1 CL150 / 300 per ASME B16.34
End Connections Flanged raised face per EN 1092-1 Flanged raised face per ASME B16.5
Valve Body/Bonnet Materials
1.0619 steel ASME SA216 WCC steel
1.4409 stainless steel ASME SA351 CF3M stainless steel
CW2M (sizes DN 25 through DN 100 only) CW2M (NPS 1 through 4 only)
ASME SA352 LCC ASME SA352 LCC
CN7M Alloy 20
(sizes DN 25 through DN 100 only)
CN7M Alloy 20
(NPS 1 through 4 only)
CDMN Duplex SST
(sizes DN 25 through DN 100 only)
CDMN Duplex SST
(NPS 1 through 4 only)
CF3 304L SST
(sizes DN 25 through DN 100 only)
CF3 304L SST
(NPS 1 through 4 only)
M35-2 (NPS 1 through 4 only)
N7M Alloy B2
(NPS 1 through 4 only)
Face-to-Face Dimensions
Consistent with EN 558-1 Series 1
Consistent with ANSI/ISA 75.08.01
Shutoff per IEC 60534-4
and ANSI/FCI 70-2
Metal seat - Class IV (standard)
Metal seat - Class V (optional)
PTFE seat - Class VI (optional)
(1)
Flow Direction Flow-up (Cavitrolâ„¢ III trim, Flow down)
Flow Control Characteristics Equal Percentage and Linear
Trim Style
Port Diameters Trim Style Description
4.8 mm Micro-Flow trim (unbalanced)
9.5, 14, 22 mm
Stem-Guided with Contoured Plug (unbalanced)
or Port-Guided with Cavitrol III trim (unbalanced)
36, 46 mm Port-Guided Plug (unbalanced)
70, 90, 136 mm Balanced Trim with Contoured plug or Unbalanced Port-Guided Plug
Handwheel Available as an option
Travel Stop Available as an option
1. For 4.8 to 14 mm ports, Class VI shutoff is achieved without PTFE seat.
Valve Installation
WARNING
Always wear protective gloves, clothing, and eyewear when performing any installation operations to avoid personal
injury.
Personal injury or equipment damage caused by sudden release of pressure or bursting of pressure retaining parts might
result if service conditions exceed those for which the product was intended. To avoid injury or damage, provide a relief
valve for over pressure protection as required by government or accepted industry codes and good engineering practices.
Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this
instruction manual.
CAUTION
This valve is intended for a specific range of pressures, temperatures and other application specifications. Applying
different pressure and temperatures to the valve could result in parts damage, malfunction of the control valve or loss of