Maintenance
PROCEDURE
A
After you turn off the projectors power, and the
confirmation buzzer beeps twice, disconnect the
power cable.
B
Wait until the lamp has cooled down, then remove the
lamp cover from the base of the projector.
Loosen the lamp cover fixing screw with the screwdriver that is
supplied with the spare lamp (or your own cross head
screwdriver).
Then slide the lamp cover straight forward and lift it to remove.
Replacing the Lamp
When replacing the lamp because it has stopped
illuminating, there is a possibility that the lamp may be
broken.
If replacing the lamp of a projector which has been
installed on the ceiling, you should always assume that
the lamp is broken, and you should stand to the side of
the lamp cover, not underneath it. Remove the lamp
cover gently. Small pieces of glass may fall out when
the lamp cover is opened. If pieces of glass get into
your eyes or mouth, seek medical advice immediately.
Wait until the lamp has cooled down sufficiently before
removing the lamp cover. If the lamp is still hot, burns
or other injuries may result. It takes about one hour
after the power has been turned off for the lamp to be
cool enough.

Table of Contents

Other manuals for Epson EMP-S4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson EMP-S4 and is the answer not in the manual?

Epson EMP-S4 Specifications

General IconGeneral
BrandEpson
ModelEMP-S4
CategoryProjector
LanguageEnglish

Related product manuals