V3X COD Modules LEDs
The following table lists the LEDs available on then V3X COD modules (from left to right):
LED Color Status Function
CPU Green Blinking Indicates CPU activity.
On There is a problem with the module processor.
PLAY Green On The module is set in play mode by the software.
Off The module is set in record mode.
PVID Green On A valid video signal has been detected on the J8
connector (SD/HD SDI input), whether the module is
in play or record mode.
TF
(transfer)
Green Blinking Data transfers occur between the module and the
H3X board.
M1 Not used.
M2
M3
M4
6.2.2. CODConnectivity in SD and HD
Connector Assignments
This section describes the connector assignments and layout for the video standards SD
525i, SD 625i, HD 1080i and HD 720p.
The specific connectivity for HD 3D/1080p Dual Link and 3D/1080p Single Link 3Gbps is
described in the following sections.
Connector SD mode HD mode
Connector
label
J1 J5 is factory-wired to the backplane instead of J1. You can
connect J1 instead of J5 if CVBS monitoring is required in
SD or HD mode.
SDI monitoring is no longer available on J1.
CHAR SD
CVBS monitoring output
(SD)
CVBS monitoring output
(SD, down-converted)
HARDWARE TECHNICAL REFERENCE MANUAL XT3 Server 11.02
6. Boards Description 75

Table of Contents

Other manuals for EVS XT-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EVS XT-3 and is the answer not in the manual?

EVS XT-3 Specifications

General IconGeneral
BrandEVS
ModelXT-3
CategoryServer
LanguageEnglish

Related product manuals