Power supplies
2.
Ref.1912
· 37 ·
DDS
HARDWARE
Connector description
The non-regenerative power supply PS-65A has the following connectors:
F. H2/4
Non-regenerative power supply, PS-65A. Connectors.
1. Power connector for the three-phase mains.
2. Power connector for the Ballast resistor connection.
3. Ground connection for the mains cable.
4. Power DC BUS supplying power to the modular drives through metal bars.
X1. Connector for inter-module communication.
X2. Connector for the basic control signals.
L+ Re Ri
2
X1
NOTE.
Currently pin 4
·
POWER BUS
ENABLE·
of connector X2 is not
used at this time.
CAUTION.
AC touch current
greater than 3.5 mA. Install
ground wire of at least 10 mm²
(Cu) or 16 mm² (Al).
X2
3
1
L+ Re Ri
L1 L2 L3
4