2.2.2 Exhaust the air of Pipe System
Exhaust the air of the pipe system after manual ink injection.
The procedures are as follow:
1. Select the System menu using the Left/Right arrow key. Press the
Enter key.
2. Select the Debug menu and then press the Enter key. The interface
is as follow.
Figure 2- 2. Debug interface
3. Open the print head front cover. Put the special effluent bottle under
the print head to catch the waste ink
4. Open the Pump, V6, V11 and V12 in the Debug interface. Keep they
open for 3 minutes
5. Open V7, and keep it open for 15 seconds
6. Close V7, and keep it close for 30 seconds.
Repeat Step 5 and 6 once.
7. Exit Debug menu. Exhausting is over.
Note
When proceeding the third step, take out of the pressure buffer, keep the
arrow up, shake it gently, make the inside air discharge totally.