EasyManuals Logo
Home>Fujitsu>Air Conditioner>AOU36RLX

Fujitsu AOU36RLX Service Instruction

Fujitsu AOU36RLX
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
3. DRY OPERATION
3-1 INDOOR UNIT CONTROL
The compressor rotation frequency shall change according to set temperature and room
temperature variation which the room temperature sensor of the indoor unit has detected
as shown in the Table 3.
Room
temperature
Room
temperature
Compressor ON
Ts+2.7 degF
(1.5 degC)
Ts+1.8 degF
(1 degC)
Compressor OFF
Compressor
ON
ON
OFF
Indoor fan
air flow mode
Air flow mode : Lo
OFF
30 5 30 120 5 (sec)
180 180
( Table 3 : Compressor frequency )
( Fig.3 : Compressor Control based on Room Temperature )
( Fig.4 : Indoor Fan Control )
01-03
Operating frequency
ABU18RULX 25Hz
30Hz
45Hz
ABU24RULX
ABU36RSLX
Ts : Setting temperature

Other manuals for Fujitsu AOU36RLX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOU36RLX and is the answer not in the manual?

Fujitsu AOU36RLX Specifications

General IconGeneral
BrandFujitsu
ModelAOU36RLX
CategoryAir Conditioner
LanguageEnglish

Related product manuals