1. Specifications
Type
Wall mounted
Inverter, Heat pump
Model name ASU9RL2 ASU12RL2
Power supply 115 V~ 60 Hz
Power supply intake Outdoor unit
Available voltage range 103.5—126.5 V
Capacity
Cooling
Rated
kW 2.64 3.52
Btu/h 9,000 12,000
Min.—Max.
kW 0.5—3.1 0.9—3.7
Btu/h 1,700—10,700 3,100—12,500
Heating
Rated
kW 2.93 4.10
Btu/h 10,000 14,000
Min.—Max.
kW 0.5—3.5 0.9—4.7
Btu/h 1,700—12,000 3,100—16,000
Heating (17°F) *
1
Rated
kW 1.93 2.46
Btu/h 6,600 8,400
Input power
Cooling
Rated
kW
0.83 1.20
Min.—Max. 0.24—1.44 0.23—1.44
Heating
Rated 0.77 1.21
Min.—Max. 0.21—1.49 0.21—1.66
Heating (17°F) *
1
Rated 0.68 0.945
Current
Cooling
Rated A
7.5 10.9
Heating 7.0 11.0
EER2 Cooling
kW/kW 3.18 2.93
Btu/hW 10.8 10.0
COP2 Heating
kW/kW 3.80 3.38
Btu/hW 13.0 11.6
SEER2 Cooling Btu/hW 16.00
HSPF2 Heating Btu/hW 9.00
Power factor
Cooling
%
96
Heating 96
Moisture removal pints/h (L/h) 2.7 (1.3) 3.8 (1.8)
Maximum operating current*
2
Cooling
A
13.0
Heating 13.5 15.0
Fan
Airflow rate
Cooling
HIGH
CFM (m
3
/h)
424 (720)
MED 353 (600)
LOW 247 (420) 250 (425)
QUIET 191 (325)
Heating
HIGH 436 (740)
MED 353 (600)
LOW 265 (450)
QUIET 191 (325)
Type × Qty Crossflow fan × 1
Motor output W 28
Sound pressure level*
3
Cooling
HIGH
dB (A)
43
MED 38
LOW 33
QUIET 23
Heating
HIGH 44
MED 38
LOW 33
QUIET 23
Heat exchanger
Dimensions (H × W × D) in (mm) 10-1/16 × 24-13/16 × 13/16 (256 × 630 × 20)
Fin pitch FPI 23
Rows × Stages 2 × 16
Pipe type Copper
Fin type Aluminum
Enclosure
Material Polystyrene
Color
White
Approximate color of Munsell N9.25/
Dimensions
(H × W × D)
Net
in (mm)
10-5/16 × 32-5/16 × 8-1/8 (262 × 820 × 206)
Gross 10-3/8 × 34-1/4 × 12-15/16 (263 × 870 × 328)
Weight
Net
lb (kg)
15 (7)
Gross 20 (9)
Connection pipe
Size
Liquid
in (mm)
Ø1/4 (Ø6.35)
Gas Ø3/8 (Ø9.52)
Method Flare
Drain hose
Material PP+HDPE
Tip diameter in (mm) Ø17/32 (Ø13.8) (I.D.), Ø19/32 to 21/32 (Ø15 to 16.8) (O.D.)
Operation range
Cooling
°F (°C) 64 to 90 (18 to 32)
%RH 80 or less
Heating °F (°C) 60 to 88 (16 to 30)
Remote controller Wireless
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80°F (26.67°CDB)/67°FWB (19.44°CWB), and outdoor temperature of 95°FDB (35°CDB)/75°FWB (23.9°CWB).
– Heating: Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 47°FDB (8.33°CDB)/43°FWB (6.11°CWB).
– *
1
: Heating (17°F): Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 17°FDB (-8.33°CDB)/15°FWB (-9.44°CWB).
– Test conditions are based on AHRI 210/240 2023.
– Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *
2
: Maximum current is maximum value when operated within the operation range.
• *
3
: Sound pressure level:
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
- 2 -
1. Specifications
WALL MOUNTED
ASU9-12RL2
WALL MOUNTED
ASU9-12RL2