EasyManuals Logo

Fujitsu ASU9RLF1 Service Manual

Fujitsu ASU9RLF1
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #61 background imageLoading...
Page #61 background image
Trouble shooting 16
EEPROM Data Corruption Error
Outdoor unit Main PCB
When the power is turned on and
When the data of the automatic correction was damaged
Detective Actuators: Detective details:
Indicate of Display:
02-21
OUTDOOR UNIT Error Method:
1. External cause 2. Main PCB defective
Forecast of Cause:
YES
NO
Test 1-2 : External cause
Check if temporary voltage drop was not generated.
Check if temporary open was not generated.
Check if ground is connected correctly or
there are no related cables near the power line.
Test 1-1 : Turn the power on again?
Error displayed again?
Test 2 : Replace Main PCB
If Test 1 do not improve the symptom, replace Main PCB(Outdoor unit).
(SERVICE PARTS INFORMATION 10)
Indoor Unit
Outdoor Unit
Operation lamp : - time Flash
ERROR CODE : [E : --]
Timer lamp: - time Flash
Monitor
ABCDEF
6
: Light ON : Light OFF n : n time blinking
2

Table of Contents

Other manuals for Fujitsu ASU9RLF1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASU9RLF1 and is the answer not in the manual?

Fujitsu ASU9RLF1 Specifications

General IconGeneral
BrandFujitsu
ModelASU9RLF1
CategoryAir Conditioner
LanguageEnglish

Related product manuals