7. Various control
7-1. Auto restart
When the power was interrupted by a power failure etc. during operation, the operation contents at
that time are memorized and when the power is recovered, operation is automatically started with
the memorized operation contents.
Operation contents
memorized when the power is
interrupted
Wall mounted (For KGTE, KMCE,
KETA, and KETE)
Floor
Compact cassette,
Mini duct, Slim duct,
Wall mounted (For KGTB KMTB,
KMCC)
Operation mode ○ ○
Setting temperature ○ ○
Fan mode setting ○ ○
Timer mode and set time
(set by wireless remote
controller)
○ ○
Airflow direction setting ○ ○
Swing ○ ○
ECONOMY operation ○ ○
10 °C HEAT operation ○ ○
Outdoor low noise operation ○ ○
Remote control setting ○ ×
WLAN LED setting ○ ×
7-2. MANUAL AUTO operation (For Wall mounted type)
When the wireless remote controller is lost or battery power dissipated, this function will work without
the remote controller.
When MANUAL AUTO button is pressed more than 3 seconds and less than 10 seconds, MANUAL
AUTO operation starts as shown in the table below. To stop operation, press the MANUAL AUTO
button for 3 seconds.
Operation mode Auto changeover
Fan mode AUTO
Timer mode Continuous (no timer setting available)
Setting temperature 24°C
Vertical airflow direction louver setting Standard
SWING Off
ECONOMY Off
Human sensor Off
7-1. Auto restart - (04-74) - 7. Various control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS