84 Operating Manual
RX2530 M4
Troubleshooting and tips
8.6 Incorrect date and time
Ê Set the date and time in the operating system or in the BIOS Setup under
the Main menu, using System Date and System Time respectively.
I Note that the operating system may affect the system time. For example,
the operating system time may deviate from the system time under
Linux, and would overwrite the system time in the default setting on
shutdown.
If the date and time are still wrong after the server has been switched off and
back on again, replace the lithium battery (for a description refer to the
"FUJITSU Server PRIMERGY RX2530 M4 Upgrade and Maintenance
Manual") or contact our customer service team.
8.7 System will not boot
The system will not boot after installing a new HDD.
SAS configuration incorrect
Ê Check the settings for the HDDs (SAS Device Configuration) and the
additional settings in the SAS configuration menu.
8.8 Drives reported as “dead” when starting
system
This error message can occur when the onboard SAS controller has RAID
functionality or the server is equipped with a PCI RAID controller.
RAID controller configuration incorrect
Ê Check and correct the settings for the drives using the RAID controller utility.
Further information is provided in the manual for the RAID controller.

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2540 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2540 M4 and is the answer not in the manual?

Fujitsu PRIMERGY RX2540 M4 Specifications

General IconGeneral
ProcessorIntel Xeon Scalable Processor Family
Form Factor2U rack server
ChipsetIntel C621
MemoryUp to 3TB DDR4
StorageUp to 24 x 2.5-inch SAS/SATA/NVMe drives or Up to 12 x 3.5-inch SAS/SATA drives
RAID SupportRAID 0, 1, 5, 6, 10, 50, 60 (with optional controller)
Expansion SlotsUp to 8x PCIe Gen3 slots
Power Supply800W or 1200W (1+1 redundant)
Memory TypeDDR4
ManagementiRMC S5 (Integrated Remote Management Controller)
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware

Related product manuals