RX2530 M4
Operating Manual 85
Troubleshooting and tips
8.9 Added drive reported as defective
RAID controller is not configured for this drive
The drive was probably installed when the system was switched off.
Ê Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê Remove and reinstall the drive while the system is switched ON.
If the drive continues to be shown as defective, then replace it.
8.10 Error message on screen
The meaning of the error message is explained in the documentation for the
relevant components and programs on the Fujitsu manuals server.
8.11 Expansion cards or onboard devices not
recognized
When an expansion card is added, other expansion cards or onboard devices
might not be recognized.
Ê Reinstall the drivers for the expansion cards or onboard devices that are not
recognized.

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2540 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2540 M4 and is the answer not in the manual?

Fujitsu PRIMERGY RX2540 M4 Specifications

General IconGeneral
ProcessorIntel Xeon Scalable Processor Family
Form Factor2U rack server
ChipsetIntel C621
MemoryUp to 3TB DDR4
StorageUp to 24 x 2.5-inch SAS/SATA/NVMe drives or Up to 12 x 3.5-inch SAS/SATA drives
RAID SupportRAID 0, 1, 5, 6, 10, 50, 60 (with optional controller)
Expansion SlotsUp to 8x PCIe Gen3 slots
Power Supply800W or 1200W (1+1 redundant)
Memory TypeDDR4
ManagementiRMC S5 (Integrated Remote Management Controller)
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware

Related product manuals