8. ALERTS
8-4
8.3 Alert Log
The alert log shows the latest 50 alerts. When the log becomes full, the oldest entry is
erased to make room for current alerts.
1. Press the MENU/ESC key to open the main menu.
2. Select [5 Alert] then [4 Alert Log] to show the alert log.
3. Press the MENU/ESC key to close the alert log.
8.4 How to Acknowledge Alerts
With the ACK/DELETE key
When an alert condition occurs, the buzzer sounds (except for a caution) and the
name of the alert appears at the bottom of the display. Press the ACK/DELETE key
to acknowledge the alert. The buzzer stops for a warning. If multiple alerts are violat-
ed, a high-priority alert is acknowledged in order.
How to acknowledge an alert from the alert list
1. Open the alert list (see section 8.2).
2. Use the cursorpad (S or T) to select the alert to acknowledge then press the NU/
CU ENT key.
How to acknowledge all alerts from the alert list
1. Open the alert list (see section 8.2).
2. Use the cursorpad (S) to select [Acknowledge All] then press the NU/CU ENT
key.
List no.
Priority
Alert number
Alert name
Date and time
of occurrence
Position of occurrence
Date and time of
acknowledgement
Date and time
when occurrence
factor is gone

Table of Contents