1. INSTALLATION
1-23
1.7.2 Fabrication of cables
Cable Sectional view, fabrication
Power
cable
DPCY-1.5
(or
equivalent)
Conductor
S = 1.5 mm
φ = 1.56 mm
2
Armor
Sheath
φ = 11.7 mm
SECTIONAL VIEW
50
6
Armor
Cut the sheath.
Vinyl tape
Sheath
15
FABRICATION
Crimp-on lug
FV1.25-5
50
Lay in clamp
where paint
was removed.
Cable for
IEC 61162
format
equipment
(JIS cable
TTYCS-1
or
equivalent)
Cable for
AD-10
format
equipment
((JIS cable
TTYCS-1Q
or
equivalent)
Conductor
S = 0.75 mm
φ = 1.11 mm
2
Armor
Shield
Sheath
φ = 10.1 mm
SECTIONAL VIEW (TTYCS-1)
Conductor
S = 0.75 mm
φ = 1.11 mm
2
Armor
Shield
Sheath
φ = 11.3 mm
SECTIONAL VIEW (TTYCS-1Q)
3
80
Armor
Braided shield
8
Twist and cut.
6
Ground wire (70)
Solder
Four cores on TTYCS-1Q
1015
Remove paint by
40 mm, clamp this
part in cable clamp.
Vinyl tape
Ground wire: Fasten to fixing screw on pcb.
FABRICATION
NOTE ON WIRING
1) Ground both this unit
and external equipment.
2) Fabricate braided shield of external equipment as follows:
- IEC 61162-1 input, AD-10 input (photo coupler): Connect to FG(frame ground).
- IEC 61162-2 input (RS-422/485): Connect to SG(signal ground).
Note: The power section of this equipment is insulated so the potential of SG and FG are the
same. If the shielding is not properly done, the data output IC may be damaged.

Table of Contents

Other manuals for Furuno SC-50

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno SC-50 and is the answer not in the manual?

Furuno SC-50 Specifications

General IconGeneral
BrandFuruno
ModelSC-50
CategoryCompass
LanguageEnglish

Related product manuals