TROUBLE SHOOTING GUIDE
Open Type Hot Plate, Solid Hot Top, Griddles And Broilers
PROBLEM POSSIBLE CAUSE SOLUTION
Burner ame too large. Incorrect setting pressure or injector. Check the setting pressure and injector.
Burner ame soft-yellow tip. Insucient primary air. Check aeration shutter setting.
Flame lifts o burner ports. Excessive primary air. Check aeration shutter setting.
Flame lights back to injector. Excessive primary air. Check aeration shutter setting.
Burner ‘pops when turned o. Excessive primary air. Check aeration shutter setting.
Delayed ignition Pilot ame too small. Check length of pilot ame.
Burner ports blocked Clean burner
Incorrect aeration. Check aeration shutter setting.
Incorrect setting pressure. Check setting pressure.
Pilot burner will not ignite. Pilot orice blocked. Clean jet.
Pilot adjusting screw closed Open and adjust ame length.
No spark to pilots. Disconnected or loose hi-tension wires. Reconnect hi-tension wires.
Defective spark module. Replace module.
Defective momentary switch. Replace switch.
No power to range. Check and restore power supply.
Pilot keeps going out. Pilot ame too small. Check pilot ame length.
Loose thermocouple connection. Tighten connection.
Faulty thermocouple. Replace thermocouple.
Faulty ame safety device. Replace ame safety device.
Low millivolt output on open circuit
tests.
Pilot ame too small. Adjust pilot ame length.
Defective thermocouple. Replace thermocouple.
Low millivolt output high in open
circuit test, but low in closed circuit test.
Faulty ame safety device. Replace ame safety tap.
Millivolt output high on closed circuit
test, but blame safety tap will not stay
open.
Faulty ame safety device. Replace ame safety tap.
Standard And Convection Ovens
PROBLEM POSSIBLE CAUSE SOLUTION
Oven too hot or not hot enough. Thermostat out of calibration. Check calibration.
Burner ame too large. Incorrect setting pressure or injector. Check the setting pressure and injector.
Burner ame soft-yellow tip. Insucient primary air. Check aeration shutter setting.
Flame lifts o burner ports Excessive primary air. Check aeration shutter setting.
Burner ‘pops when turned o. Excessive primary air. Check aeration shutter setting.
Delayed ignition. Pilot ame too small. Check length of pilot ame.
Burner ports blocked Clean burner
Incorrect aeration. Check aeration shutter setting.
Incorrect setting pressure. Check setting pressure.
Pilot burner will not ignite. Pilot orice blocked. Clean jet.
Pilot adjusting screw closed Open and adjust ame length.
No spark to pilots. Disconnected or loose hi-tension wires. Reconnect hi-tension wires.
Defective spark module. Replace module.
Defective momentary switch. Replace switch.
No power to range. Check and restore power supply.
Pilot keeps going out. Pilot ame too small. Check pilot ame length.
Loose thermocouple connection. Tighten connection.
Faulty thermocouple. Replace thermocouple.
Faulty ame safety device. Replace ame safety device.

Table of Contents

Other manuals for Garland Master Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Garland Master Series and is the answer not in the manual?

Garland Master Series Specifications

General IconGeneral
BrandGarland
ModelMaster Series
CategoryOven
LanguageEnglish

Related product manuals