Hot Gas Path Inspection — Reassembly ProceduresInspection and Maintenance — GEK 107048
HGP-R-3
Figure HGP-R.1. Eccentric Pin Retaining Strap Weld.
First Stage
Nozzle Lower Half
Section
Turbine
Casing
Eccentric Pin
Retaining Strap
0.57
0.43
(2 Places)
0.43
0.33
(4 Places)
0.25
(3 Places)
Fig. F–1
Col. –AE