Operation 6
0020239562_02 EASICOM 3 Installation and maintenance instructions 15
≤ 30 mm
NL
X1
230V~
RT
6. Carry out the wiring. ( Page 14)
7. Screw the supplied plug to a three-core power supply
cable that complies with the relevant standards.
8. Connect the plug for the power supply cable.
9. Make sure that access to the power supply is always
available and is not covered or blocked.
10. Close the electronics box. ( Page 14)
5.6.5 Connecting controls to the electronics
X2
X22
X41
+
24V=
RT BUS
Burner
off
X106
BUS24 V
BUSRTB.off
B
ur
ner
off
R
T
24V
=
-
+
B
U
S
1
4
32
1 Safety thermostat for
floor-standing heating
2 24 V controller
3 eBUS controller or radio
receiver unit
4 Outside temperature
sensor, wired
1. Open the electronics box. ( Page 14)
2. Carry out the wiring. ( Page 14)
3. Connect the individual components depending on the
installation type.
Conditions: If installing a multi-circuit control.
Change the pump mode (d.18) from Eco (intermittent
pump operation) to Comfort (continuous pump opera-
tion).
Conditions: If you are connecting a control (230 V).
≤ 30 mm
NL
X1
230V~
RT
Connect the control to the main plug.
Remove the bridge from the plug 24V=RT.
4. Close the electronics box. ( Page 14)
6 Operation
6.1 Using diagnostics codes
You can use the parameters marked as adjustable in the
table of diagnostics codes to adapt the product to the system
and customer requirements.
Overview of diagnostics codes ( Page 30)
6.1.1 Activating diagnostics codes
1.
Press and hold the button for 7 seconds.
is shown in the display.
2.
Press the or button to set the value.
The access code (96) is reserved for the competent
person.
The access code (35) is reserved for the customer
service.
3.
Press the button to confirm.
is shown in the display.
6.1.2 Setting a diagnostics code
1.
Press the or button to select the diagnostics
code.
2.
Press the button to confirm.
The value and/or status of the diagnostics code is
shown in the display.
3.
Press the or button to set the value.
4. If you allow the value to flash for three seconds, the
setting is automatically confirmed.
is shown in the display for 1 second.
Note
You can manually confirm the setting at any
time by pressing and holding the button
for less than 3 seconds.

Table of Contents

Other manuals for Glow-worm Easicom 3 28c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm Easicom 3 28c and is the answer not in the manual?

Glow-worm Easicom 3 28c Specifications

General IconGeneral
BrandGlow-worm
ModelEasicom 3 28c
CategoryBoiler
LanguageEnglish

Related product manuals