29
05 Installation
User Manual V1.6-2024-03-20
CAUTION
• Operations such as transportation, turnover, installation and so on must meet the
requirements of the laws and regulations of the country or region where it is located.
• Move the inverter to the site before installation. Follow the instructions below to avoid
personal injury or equipment damage.
1. Consider the weight of the equipment before moving it. Assign enough personnel to
move the equipment to avoid personal injury.
2. Wear safety gloves to avoid personal injury.
3. Keep balance to avoid falling down when moving the equipment.
5.2 Inverter Installation
5.2.2 Installing the Inverter
5.2.1 Moving the Inverter
NOTICE
• Avoid the water pipes and cables buried in the wall when drilling holes.
• Wear goggles and a dust mask to prevent the dust from being inhaled or contacting eyes
when drilling holes.
• Make sure the inverter is rmly installed in case of falling down.
• The DC switch lock of appropriate size should be prepared by customers. The diameter of
the lock hole is 5mm. The lock might not be able to install if the size is inappropriate.
Step 1: Put the plate on the wall horizontally and mark positions for drilling holes.
Step 2: Drill holes to a depth of 80mm using the hammer drill. The diameter of the drill bit
should be 8mm.
Step 3: Use the expansion bolts to x the inverter on the wall.
Step 4: (Optional) Secure the DC switch with the DC switch lock, ensuring that the DC switch is
"OFF" during installation.
Step 5: Install the inverter on the mounting plate. For models with handles, please lift the
inverter using the handles. For models without handles, please lift the inverter directly.
Step 6: Tighten the nuts to secure the mounting plate and the inverter.