Storage
332689D 25
Storage
Short Term Storage
(up to 2 days)
1. Relieve pressure, page 13.
2. Leave suction tube and prime tube in paint pail.
3. Cover paint pail and hoses tightly with plastic wrap.
4.
a. Engage trigger lock.
b. Leave gun attached to hose.
c. If you have not already cleaned them, remove
tip and guard from gun and clean with water or
flushing solvent. A soft brush can be used to
loosen and remove dried on material if needed.
d. Wipe paint off outside of gun using a soft cloth
moistened with water or flushing solvent.
Long Term Storage
(more than 2 days)
Always circulate Pump Armor storage fluid through sys-
tem after cleaning. Water left in sprayer will corrode and
damage pump. Follow Shutdown and Cleaning, page
20, or Power Flush Cleaning, page 22.
1. Place suction tube in Pump Armor storage fluid bot-
tle and prime tube in waste pail.
2. Move Prime/Spray valve to PRIME.
3. Turn power switch ON.
4. Turn pressure control knob clockwise until the pump
turns on.