27
Air to Water Heat Pump
Service Manual- Versati II Series
CONTROL
No� Full Name
Displayed
Name
Range(
) Range(
) Default
1
Water out temperature
for cooling
WOT-Cool
7~25
[With FCU]
18~25
[Without FCU]
45~77
[With FCU]
64~77
[Without FCU]
7
/45
[With FCU]
18
/64
[Without FCU]
2
Water out temperature
for heating
WOT-Heat
25~55
[High temp.]
25~45
[Low temp.]
77~131
[High temp.]
77~113
[Low temp.]
45
/113
[High temp.]
35
/95
[Low temp.]
3
Room temperature for
cooling
RT-Cool 18~30
64~86
20
/68
4
Room temperature for
heating
RT-Heat 18~30
64~86
26
/79
5 Tank temperature T-water tank 40~80
104~176
50
/122
6
Eheater-on ambient
temperature
T-Eheater -20~18
-4~64
0
/32
7
Extra-heater-on
ambient temperature
T-Extraheater -20~18
-4~64
0
/32
8
Max heat pump
waterout temperature
(no eheater)
T-HP Max 40~50
104~122
50
/122
9
Lower limit ambient
temperature at the auto
mode for heating
Lower AT-Heat
-20~5
-4~41
-15
/5
10
Upper limit temperature
at the auto mode for
heating
Upper AT-Heat
10~20
50~68
15
/59
11
Upper limit room
temperature at the auto
mode for heating
Upper RT-Heat
22~30
72~86
24
/75
12
Lower limit room
temperature at the auto
mode for heating
Lower RT-Heat
18~21
64~70
20
/68
13
Upper limit water-out
temperature at the auto
mode for heating
Upper WT-Heat
46~55
[High temp.]
30~35
[Low temp.]
115~131
[High temp.]
86~95
[Low temp.]
48
/118
[High temp.]
35
/95
[Low temp.]
14
Lower limit water-out
temperature at the auto
mode for heating
Lower WT-Heat
36~45
[High temp.]
25~29
[Low temp.]
97~113
[High temp.]
77~84
[Low temp.]
40
/104
[High temp.]
29
/84
[Low temp.]
15
Lower limit ambient
temperature at the auto
mode for cooling
Lower AT-Cool
10~25
50~77
25
/77
16
Upper limit temperature
at the auto mode for
cooling
Upper AT-Cool
26~48
79~118
40
/104
17
Upper limit room
temperature at the auto
mode for cooling
Upper RT-Cool
24~30
75~86
27
/81
18
Lower limit room
temperature at the auto
mode for cooling
Lower RT-Cool
18~23
64~73
22
/72
19
Upper limit water-out
temperature at the auto
mode for cooling
Upper WT-Cool
15~25
[With FCU]
22~25
[Without FCU]
59~77
[With FCU]
72~77
[Without FCU]
15
/59
[With FCU]
23
/73
[Without FCU]
20
Lower limit water-out
temperature at the auto
mode for cooling
Lower WT-Cool
7~14
[With FCU]
18~21
[Without FCU]
45~57
[With FCU]
64~70
[Without FCU]
7
/45
[With FCU]
18
/64
[Without FCU]
21
Temperature deviation
for cooling
T-Cool 2~10
36~50
5
/41
22
Temperature deviation
for heatling
T-Heat 2~10
36~50
10
/50
23
Temperature deviation
for heating water
T-hot water 2~8
36~46
5
/41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree Versati II Series and is the answer not in the manual?

Gree Versati II Series Specifications

General IconGeneral
BrandGree
ModelVersati II Series
CategoryHeat Pump
LanguageEnglish

Related product manuals