C. Loss of Power
Minimizing Smoke During Loss of Power Using Battery
Back-up
Harman® strongly recommends installing battery back-
up to minimize entry of smoke into the room in the
event of power loss.
Your pellet/biomass burning appliance relies on a
combustionblowertoremoveexhaust.Apowerfailurewill
cause the combustion blower to stop. This may lead to
exhaustseepingintotheroom.Verticalriseintheventing
may provide natural draft. It is, however, no guarantee
againstleakage.
There are two Harman® approved battery back-up
options for your appliance:
Uninterruptible Power Supply UPSbatteryback-upsare
availableonlineoratcomputerandofceequipmentstores.
Your Harman® appliance with Rev E or later software
available beginning in November 2010 may be plugged
directlyintoaHarman®approvedUPS:
• The APC (American Power Conversion) model
#BE750GandtheTrippLitemodelINTERNET750Uare
testedandapproved.Otherbrandsormodelsmaynot
becompatible.
Whenpowerislost,afullychargedUPSwillpowerasafe,
combustion blower only shut-down. Your appliance will
pulsetheblowereveryfewsecondstoclearexhaustuntil
thereisout. NOTE: The UPS provides safe shut-down
only. It is not intended for continued operation.
• TheSurere512connectstoa12voltdeepcyclebattery
thatwillrunyourapplianceforup to eight (8) hours.It
includesatricklechargefeaturethatkeepsyourbattery
chargedwhenpowerisavailable.NOTE:Ifthepoweris
outforlongerthanbatterylife,smokeleakagemaystill
occurunlessyourstovehasbeensafelyshutdown.
Yourappliancewillrecognizewhenpowerisrestored.What
happens depends on ESP temperature and whether it is
equippedwithautomaticignition:
In “Automatic” Mode,units equipped with automatic
ignitionwillrespondtothesetpointandESPtemperature
andresumenormaloperation.
In “Idle” Mode,orforunitswithoutautomaticignition:
• If the ESP is cool, the appliance will remain shut
down.
• IfthereisoutandtheESPisstillwarm,thefeeder
mayrestart.Sincethereisout,theESPtemperature
willnotrise.Theunitwillthenshut-down,andmay
ashasix-blinkstatuserror.(SeeESPerrorcodes)
• If the re is still burning, it will resume normal
operation.
Contact your dealer if you have questions about UPS
compatibilitywithyourappliance.
Use only Harman
®
approved battery back-up devices.
Other products may not operate properly, can create
unsafe conditions or damage your appliance.
CAUTION
Always keep appliance doors and hopper lid closed
and latched during operation and during power
failures to minimize risk of smoke or burn-back.
D. Emergency Manual Ignition
Harman
®
pellet stoves and inserts should be lit using the
automatic ignition system. This is the safest and most
reliablewayforignitingtheunit.Intheeventtheautomatic
igniterisnotfunctioning,thestepsbelowmaybefollowed
tomanuallylightthestoveorinsertinthe“ConstantBurn”
mode. Manual lighting is for emergency purposes only,
andtheignitershouldberepairedorreplacedassoonas
practical.
WARNING
!
Only use restarter commercially marketed for pellet
stoves and inserts, including wax coated wood chips,
pellet starter gel and pellet igniter blocks. Use of any
othertypeofrestarterisprohibited.
To avoid serious injury or death read and follow
manufacturer’swarningandinstructionsforuseofrestarter.
Useofrestarterisonlypermittedwhenperformingacold
start.
Neverattempt to manuallylighta stove orinsert that has
been operated recently and is not at room temperature.
If automatic ignition was attempted, be sure to give the
stoveorinsertatleast30minutesorlongertocooltoroom
temperature.
Besurethatthestoveorinsertisinthe“Igniter-Disabled”
modeofoperation.
Once all the precautions have been taken, follow these
steps:
1.TurntheModeSelectorto“OFF”.
2.Fillburnpotwithpellets,onlyhalfway.(DoNotOverFill).
3.Add firestarter to pellets following manufacturer’s
instructions.
4. Lightpelletgelwithamatch,andclosethedoor,turnMode
SelectortoConstantBurn.Operationwillbeginwhenthe
rereachesthepropertemperature.
WARNING
!