Harman® • P-Series Installation Manual_R18 • 2014 - ___ • 06/1810 3-90-436168i
C. Floor Protection
Parallel Installation:
Place the stove on a noncombustible type oor or oor
protector that extends a minimum of 6 inches (152mm) to
the front of the load door opening, 6 inches (152mm) to the
sides of the door opening, and 6 inches to the rear.
TheP-SeriesdoesnotrequireRvalueoorprotection.
Theminimumoorprotectormaterialis20gaugesheetmetal.
OtheroorprotectormaterialsthatcanbeusedincludeType
I hearth pads, ceramic tile, stone, brick, etc. Figure 3.3
*Floor protection dimensions for the front and sides are
measured from the appliance door opening in The United
States. In Canada, the side dimension is measured from the
widest part of the appliance.
P43-Minimumsizerectangularoorprotectionis25-7/16”
Wide by 26-3/4” Deep (646mm X 680mm).
P61A-Minimumsizerectangularoorprotectionis25-1/8”
Wide by 27-3/4” Deep (638mm X 705mm).
P68-Minimumsizerectangularoorprotectionis25-3/16”
Wide by 27-3/4” Deep (640mm X 705mm).
Venting:
US - Follow PL vent manufacturers recommendations when
conguringventpipeinstallation.
Canada - Must extend 2” (51mm) beyond each side of any
horizontaluepipe.
Figure 3.3
J
K
L
Floor protector
D. Mobile Home Installation
When installing this unit in a mobile home, several
requirements must be followed:
1. Theunit must beboltedtothe oor.Thiscanbedone
using an appropriate fastener for the application.
2. The unit must also be connected to outside air. See
Termination Location and Vent Information” Section D.
3. Floor protection and clearances must be followed as
shown.
4. The appliance must be properly grounded to the frame of
the mobile home using a minimum of 8 AWG copper solid
or stranded, insulated or bare wire or equivalent.
Floor Protection
Requirements
US Canada
J Sides 6" 152mm
K Front 6” 152mm
L Rear 6” 152mm
Corner Installation:
Minimumsizeoorprotectionforacornerinstallationhearth
pad is:
P43-Minimumsizeoorprotectionis25-7/16”Wideby26-
3/4” Deep (646mm X 680mm).
P61A-Minimumsizeoorprotectionis25-1/8”Wideby27-
3/4” Deep (638mm X 705mm).
P68-Minimumsizeoorprotectionis25-3/16”Wideby27-
3/4” Deep (640mm X 705mm).
Note: Floor protector WILL NOT touch the wall using
minimum clearances.
If corner oor protection is desired to touch the wall, the
oorprotectionwillneedtobeatleast40”x40”(1016mm
x 1016mm). Note: This will allow the oor protection to
touch the wall as shown. Figure 3.4.
Alternateoorprotectordimensionmaybeusedaslongas
they satisfy the measurement requirements shown below.
Figure 3.4