C. Floor Protection
Parallel Installation:
Place the stove on a noncombustible type oor or oor
protector that extends a minimum of 6 inches (152mm) to
the front of the load door opening, 6 inches (152mm) to the
sides of the door opening, and 6 inches to the rear.
TheP-SeriesdoesnotrequireRvalueoorprotection.
Theminimumoorprotectormaterialis20gaugesheetmetal.
OtheroorprotectormaterialsthatcanbeusedincludeType
I hearth pads, ceramic tile, stone, brick, etc. Figure 3.3
*Floor protection dimensions for the front and sides are
measured from the appliance door opening in The United
States. In Canada, the side dimension is measured from the
widest part of the appliance.
P43-Minimumsizerectangularoorprotectionis25-7/16”
Wide by 26-3/4” Deep (646mm X 680mm).
P61A-Minimumsizerectangularoorprotectionis25-1/8”
Wide by 27-3/4” Deep (638mm X 705mm).
P68-Minimumsizerectangularoorprotectionis25-3/16”
Wide by 27-3/4” Deep (640mm X 705mm).
Venting:
US - Follow PL vent manufacturers recommendations when
conguringventpipeinstallation.
Canada - Must extend 2” (51mm) beyond each side of any
horizontaluepipe.
Figure 3.3
J
K
L
Floor protector
D. Mobile Home Installation
When installing this unit in a mobile home, several
requirements must be followed:
1. Theunit must beboltedtothe oor.Thiscanbedone
using an appropriate fastener for the application.
2. The unit must also be connected to outside air. See
“Termination Location and Vent Information” Section D.
3. Floor protection and clearances must be followed as
shown.
4. The appliance must be properly grounded to the frame of
the mobile home using a minimum of 8 AWG copper solid
or stranded, insulated or bare wire or equivalent.
Floor Protection
Requirements
US Canada
J Sides 6" 152mm
K Front 6” 152mm
L Rear 6” 152mm
Corner Installation:
Minimumsizeoorprotectionforacornerinstallationhearth
pad is:
P43-Minimumsizeoorprotectionis25-7/16”Wideby26-
3/4” Deep (646mm X 680mm).
P61A-Minimumsizeoorprotectionis25-1/8”Wideby27-
3/4” Deep (638mm X 705mm).
P68-Minimumsizeoorprotectionis25-3/16”Wideby27-
3/4” Deep (640mm X 705mm).
Note: Floor protector WILL NOT touch the wall using
minimum clearances.
If corner oor protection is desired to touch the wall, the
oorprotectionwillneedtobeatleast40”x40”(1016mm
x 1016mm). Note: This will allow the oor protection to
touch the wall as shown. Figure 3.4.
Alternateoorprotectordimensionmaybeusedaslongas
they satisfy the measurement requirements shown below.
Figure 3.4