Harman® • P-Series Installation Manual_R18 • 2014 - ___ • 06/186 3-90-436168i
A. Design and Installation Considerations
1. Appliance Location
NOTICE: Check building codes prior to installation.
Installation MUST comply with local, regional, state
and national codes and regulations.
Consult insurance carrier, local building inspector,
re ofcials or authorities having jurisdiction over
restrictions, installation inspection and permits.
It is a good idea to plan your installation on paper, using exact
measurementsfor clearances and oor protection,before
actually beginning the installation
Consideration must be given to:
• Safety,convenience,trafcow
Placement of the chimney and chimney connector.
If you are not using an existing chimney, place the
appliance where there will be a clear passage for a
factory-built listed chimney through the ceiling and
roof.
Installing an optional outside air kit would affect the
location of the vent termination.
Since pellet exhaust can contain ash, soot or sparks, you
must consider the location of:
• Windows
Air Intakes
Air Conditioner
• Overhang,softs,porchroofs,adjacentwalls
Landscaping, vegetation
Marginal Location:
Below peak
Location NOT recommended:
Not the highest point of the roof
Wind loading possible
Multi-level Roofs
Windward
Leeward
Recommended:
Outside Air Intake
on windward side
NOT recommended:
Outside Air Intake
on leeward side
Recommended Location:
Above peak
Recommended:
Insulated exterior chase
in cooler climates
Recommended Location:
Above peak
Inside heated space
Location NOT recommended:
Too close to tree
Below adjacent structure
Lower roof line
Avoid outside wall
Marginal Location:
Wind loading possible
Figure 2.1
2
Getting Started
When locating vent and venting termination, vent above
roof line when possible.
Warning! Risk of Fire Damaged parts could impair safe
operation. Do NOT install damaged, incomplete or substitute
components.
NOTICE: Locating the appliance in a location of considerable
air movement can cause intermittent smoke spillage from
appliance. Do not locate appliance near:
Frequently open doors
Central heat outlets or returns
Installation and service of this
appliance should be performed by
qualiedpersonnel.Hearth&Home
Technologies recommends HHT
Factory Trained or NFI Certied
professionals.
Check building codes prior to installation.
Installation MUST comply with local, regional, state and
national codes and regulations.
• Contactlocalbuildingorreofcialsaboutrestrictions
and installation inspection requirements in your area.
CAUTION
!