23
Note: Separate chlorinator output levels for the pool and spa must be set. If the valves
are in the pool-only or spa spillover positions, then the chlorinator will operate accord-
ing the pool setting. If the valves are in the spa-only position then the chlorinator will
operate according to the spa setting. The actual amount of chlorine introduced into the
pool/spa is determined by: this output setting, the amount of time the filter pump is
running, the water temperature, and the amount of salt in the water. Also see Start/Stop
Superchlorination below.
Start/Stop Superchlorination
1. Press the “MENU” button repeatedly until “Settings Menu” is displayed
2. Press the “>” button repeatedly until “Super Chlorinate” is displayed.
3. The display will show whether superchlorination is “on” or “off”.
4. Press “+” or “-“ to toggle between “on” and “off”
Note: Once started, superchlorination will run for the programmed number of hours
(Timers Menu/Super Chlorinate Hours) or until you manually turn it off.
Superchlorination may be temporarily interrupted for a programmed spa operation.
Program a Timeclock
1. Press the “MENU” button repeatedly until “Timers Menu” is displayed
2. Press the “>” button repeatedly until “xxx—all” or “xxx—wkend” (where xxx is the parameter
that you want to program) is displayed.
3. Use the “+” and “-“ buttons to set the desired start time, then press “>” to switch to the off
time. Use the “+” and “-“ buttons to adjust the off time. If you are setting the “weekend”
timeclock, press “>” to go to the “weekday” settings.
Note: During the programmed time, there may be other automatic or manual opera-
tions that prevent the relay/valve from operating—see a more detailed discussion under
Automatic System Operation/Timers Menu/Aux Timeclock or in Troubleshooting/Diag-
nostic Information.
Program a Countdown Timer
1. Press the “MENU” button repeatedly until “Timers Menu” is displayed
2. Press the “>” button repeatedly until the “xxx—Timer” (where xxx is the parameter that you
want to program) is displayed.
3. Use the “+” and “-“ buttons to set the desired timer period.
Note: A setting of 0:00 will display as “manual on/off”. The countdown automatic
turn off function is disabled but manual operation is still permitted. There may be other
automatic or manual operations that prevent the relay/valve from operating—see a
more detailed discussion under Automatic System Operation/Timers Menu/Aux Timeclock
or in Troubleshooting/Diagnostic Information.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward Goldline Controls Aqua Logic AQL-P-4 and is the answer not in the manual?

Hayward Goldline Controls Aqua Logic AQL-P-4 Specifications

General IconGeneral
BrandHayward
ModelGoldline Controls Aqua Logic AQL-P-4
CategoryLighting Equipment
LanguageEnglish

Related product manuals