30
Troubleshooting and Diagnostic Information
The Aqua Logic provides 2 different tools to aid in troubleshooting any problems that may occur in your
pool and/or spa system. The Service mode will allow you to disable automatic operation and manually
control most of the equipment (the heater and general purpose Valve3 output are the exceptions). The
Diagnostic Menu will provide some detailed information regarding system operation.
While both of the features are primarily intended for the use of the professional service technician, their
function is fully explained below. If you believe your system is not operating properly or have questions
regarding the operation, call the Goldline Technical Service Department from Monday through Friday,
8AM to 8PM EST at 888-921-7665.
Service Mode
The main unit keypad has a SERVICE button that is used primarily during servicing of the pool equipment.
If you want to completely disable the automatic operation and operate the system manually, you can put
the system into Service or Service-Timed mode by pressing the “Service” button. Pressing the “SER-
VICE” button once will switch the system into service mode which means that all automatic functions are
disabled, the optional remote display/keypads are disabled (except for manual turn off for emergencies).
The outputs can be manually controlled by pressing the buttons on the local display/keypad. The red
“SERVICE” LED will be illuminated and the Aqua Logic will remain in this mode of operation until manu-
ally taken out of service mode.
Pressing the “SERVICE” button again will cause the Aqua Logic to switch to service-timed mode which is
very similar to service mode, except that the Aqua Logic will automatically return to normal operation after
3 hours. During service timed operation, the “SERVICE” LED will flash and the time remaining will be
displayed on the remote display/keypad(s).
Pressing the “SERVICE” button again, will return the Aqua Logic to normal (automatic) operation.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward Goldline Controls Aqua Logic AQL-P-4 and is the answer not in the manual?

Hayward Goldline Controls Aqua Logic AQL-P-4 Specifications

General IconGeneral
BrandHayward
ModelGoldline Controls Aqua Logic AQL-P-4
CategoryLighting Equipment
LanguageEnglish

Related product manuals