EasyManuals Logo
Home>Hayward>Heater>HDF275

Hayward HDF275 User Manual

Hayward HDF275
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
Inspect the Ignitor & Blower wiring. Verify
insulation is not damaged. IF wires are damaged,
replace the damaged part (pg. 25). IF OK, go to 4B.
Verify ignitor resistance
Disconnect ignitor from ICB & measure resistance
of ignitor. Verify 8-25 ohms between 20°-140°F. IF
correct, go to 4C. IF NOT, replace ignitor (pg. 25).
Ignitor and blower wiring
37
4. Open FC4 Fuse
Step 4A
Measure blower resistance
Measure for 13-18 ohms across the black and
white (red wire not used) terminal wires. IF out-of-
range, replace blower (pg. 25). IF correct, contact
technical support (908)355-7995.
Step 4C
Step 4B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward HDF275 and is the answer not in the manual?

Hayward HDF275 Specifications

General IconGeneral
BrandHayward
ModelHDF275
CategoryHeater
LanguageEnglish

Related product manuals