9
How To: Program Heater Bypass Operation
Follow the included steps to place the heater in bypass operation for external control.
NOTE: the maximum temperature set point is 104° F.
Press the ‘MENU ICON’ button to place the
heater in ‘STANDBY’.
Press and hold the ‘MINUS’ button and ‘MENU
ICON’ button for 3 seconds.
bowill appear on the display when the
heater has successfully entered bypass
operation.
Once in bypass, press the ‘MENU ICON ’
button until ‘POOL’ or ‘SPAis illuminated.
Step 2
Step 3
Step 4
Step 1