EasyManuals Logo
Home>Hayward>Water Pump>Max-Flo XL

Hayward Max-Flo XL User Manual

Hayward Max-Flo XL
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 16 of 20 Max-Flo XL Pump IS2300 Rev-A1
Ref.
No.
Part No. Description Qty.
9
SPX23
00B
Diffuser
1
10
SPX2700C
Impeller for ¾ HP Max
-
Rate Pump
1
SPX2700CSP
Impeller for Pump model SP2305X7EESP
1
SPX2707CM
Impeller for 1 HP Max
-
Rate Pump
1
SPX2710CM
Impeller for 1 ½ HP Max
-
Rate Pump
1
SPX2715CM
Impeller for 2 HP Max
-
Rate Pump
1
11
GMX600F
Housing O
-
Ring
1
12
SPX2700SA
Shaft Seal Assembly
1
13
SPX23
00E
Seal Plate
1
14
SPX3200Z5
PAK4
Motor Bolt
(4 Pack)
1
15
SPX23
00G
Motor Support
with Base Mount Screws
1
16
SPX1600Z52
Motor Supp
ort Base Mount Screws
1
17
SP
X
2700UNKIT
Union Connector Kit (Includes 2 Nuts, Connectors, Gaskets)
1
OPTIONAL
18
SP
X
2300GR
Optional Riser Base Aligns with Sta
-
Rite
®
Dyna
-
Pro
®
1
MOTORS
SPX2705Z1M
Motor, ¾ HP, Threaded Shaft (Single Phase, 60 Cyc
le 115V/
208
-
230V)
1
SPX2705Z1ME
Motor, ¾ HP, Energy Eff. Threaded Shaft (Single Phase, 60 Cycle 115/208
-
230V)
1
SPX2707Z1M
Motor, 1 HP, Threaded Shaft (Single Phase, 60 Cycle 115/
208
-
230V)
1
SPX2710Z1M
Motor, 1
-
1/2 HP, Threaded Shaft (Single Phase, 6
0 Cycle 115/
208
-
230V)
1
SPX2715Z1ME
Motor, 2 HP,
Energy Eff.,
Threaded Shaft (Single Phase, 60 Cycle 115/
208
-
230V)
1
SPX2707Z2M
Motor, 1 HP, Two Speed, Threaded Sh
aft (Single Phase, 60 Cycle
230V)
1
SPX2710Z2M
Motor, 1
-
1/2 HP, Two Speed, Threaded Sh
a
ft (Single Phase, 60 Cycle
230V)
1
SPX2715Z2M
Motor, 2 HP, Two Speed, Threaded Sh
aft (Single Phase, 60 Cycle
230V)
1
9. Troubleshooting
9.1. General Problems
Motor Will NOT Start:
1. Make sure the terminal board connections agree with the wiring diagram on the pump data plate label.
2. Be sure the pump is wired for the available field supply voltage.
3. Check for and correct any improper or loose wiring connections; open switches or relays; tripped circuit
breakers, or blown fuses.
4. Manually check rotation of the motor shaft for free movement and lack of obstruction. Correct if necessary.
Motor Shuts OFF:
1. Check for low voltage or power drop at the motor (frequently caused by undersized wiring). Contact a
qualified professional to verify the electrical connections and that the voltage is within +/- 10% of the motor
nameplate voltage rating.
Motor Hums, But Does NOT Start:
1. Check power supply voltage. Contact a qualified professional if the voltage is more than 10% lower than the
motor nameplate voltage rating.
2. Impeller jammed with debris. Have a qualified repair professional open the pump and remove the debris.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward Max-Flo XL and is the answer not in the manual?

Hayward Max-Flo XL Specifications

General IconGeneral
BrandHayward
ModelMax-Flo XL
CategoryWater Pump
LanguageEnglish

Related product manuals