USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 16 of 20 Max-Flo XL Pump IS2300 Rev-A1
No.
Part No. Description Qty.
Impeller for Pump model SP2305X7EESP
Union Connector Kit (Includes 2 Nuts, Connectors, Gaskets)
Optional Riser Base Aligns with Sta
Motor, ¾ HP, Threaded Shaft (Single Phase, 60 Cyc
Motor, ¾ HP, Energy Eff. Threaded Shaft (Single Phase, 60 Cycle 115/208
Motor, 1 HP, Threaded Shaft (Single Phase, 60 Cycle 115/
1/2 HP, Threaded Shaft (Single Phase, 6
Threaded Shaft (Single Phase, 60 Cycle 115/
Motor, 1 HP, Two Speed, Threaded Sh
aft (Single Phase, 60 Cycle
1/2 HP, Two Speed, Threaded Sh
ft (Single Phase, 60 Cycle
Motor, 2 HP, Two Speed, Threaded Sh
aft (Single Phase, 60 Cycle
9. Troubleshooting
9.1. General Problems
Motor Will NOT Start:
1. Make sure the terminal board connections agree with the wiring diagram on the pump data plate label.
2. Be sure the pump is wired for the available field supply voltage.
3. Check for and correct any improper or loose wiring connections; open switches or relays; tripped circuit
breakers, or blown fuses.
4. Manually check rotation of the motor shaft for free movement and lack of obstruction. Correct if necessary.
Motor Shuts OFF:
1. Check for low voltage or power drop at the motor (frequently caused by undersized wiring). Contact a
qualified professional to verify the electrical connections and that the voltage is within +/- 10% of the motor
nameplate voltage rating.
Motor Hums, But Does NOT Start:
1. Check power supply voltage. Contact a qualified professional if the voltage is more than 10% lower than the
motor nameplate voltage rating.
2. Impeller jammed with debris. Have a qualified repair professional open the pump and remove the debris.