Thermal Monocular User Manual
14
Note
If digital zoom is enabled, only the PIP view zooms.
3.9 Flat Field Correction
This function can correct non-uniformity of display.
Steps
1. Hold to go to the menu.
2. Select and press to switch FFC mode.
Manual: Hold in live view to correct the non-uniformity of display.
Auto: The device performs FFC automatically according to the set schedule when switching
on the camera.
External: Cover the lens cover, then hold in live view to correct the non-uniformity of
display.
3. Hold to save the settings and exit.
Note
The countdown will start before the device performs FFC automatically.
3.10 Correct Defective Pixel
The device can correct the defective pixels on the screen which are not performed as expected.
Steps
1. Hold to show the menu.
2. Select and press to enter the DPC setting interface.
3. On the DPC setting interface, press to select Axis, and press to switch the moving
direction of the cursor. If you select X, the cursor moves left and right; if you select Y, the cursor
moves up and down.
4. Press or to move the cursor until it reaches the defective pixel, and press to
select Axis to N.
5. Press or to select DPC, and press correct the defective pixel.
6. Hold to exit.
Note
The selected defective pixel can be magnified and displayed at the bottom right of the interface.

Questions and Answers: