User Manual of Network Video Recorder
127
8.6 Handling Exceptions Alarm
Purpose:
Exception settings refer to the handling action of various exceptions, e.g.
• HDD Full: The HDD is full.
• HDD Error: Writing HDD error or unformatted HDD.
• Network Disconnected: Disconnected network cable.
• IP Conflicted: Duplicated IP address.
• Illegal Login: Incorrect user ID or password.
• Record Exception: No space for saving recorded files.
• PoE Power Overload: The power consumption of the connected cameras via the PoE interface exceeds the
maximum PoE power.
PoE Power Overload is only supported by DS-7600NI-SE/P series NVR.
Steps:
Enter Exception interface of System Configuration and handle various exceptions.
Menu> Configuration> Exceptions
Please refer to Chapter Setting Alarm Response Actions for detailed alarm response actions.
Figure 8. 15 Exceptions Setup Interface