2.
Press a zone to pop up the zone eding dialogue box.
3.
Set the zone type, alarm type, status of arming status, entering delay, and exing delay.
4.
Tap OK to save the sengs.
Note
●
7 zone types are selectable: Panic Buon, Door Magnec, Smoke Detector, Acve Infrared,
Passive Infrared, Gas Detector, and Doorbell.
●
3 alarm types are selectable: 24h Alarm, Instant Alarm, and Delay Alarm.
Set the alarm type as 24h alarm, and the zone will be armed for 24h.
Set the alarm type as instant alarm, and the zone will alarm once it's triggered.
Set the alarm type as delay alarm, and you should set the entering delay
duraon and exing
delay duraon.
●
Both the entering delay
duraon and the exing delay duraon are from 30s to 60s.
●
For Gas Detector, Smoke Detector and doorbell, the alarm type is set as default 24h alarm.
The alarm type of them can not be changed.
Arming Mode Sengs
4 arming modes can be congured: stay mode, away mode, sleeping mode and custom mode.
Before You Start
Tap Sengs → → Shortcut Sengs to enable Alarm.
Steps
Note
On the home page, the arming status funcon and zone sengs funcon are hidden by default.
You should enable the alarm funcon rst.
1.
Back to the home page, tap Sengs → → Scene Sengs to enter the arming mode sengs
page.
2.
Tap Stay Mode, Away Mode, Sleeping Mode, or Custom to enter the page.
Network Indoor Staon Conguraon Guide
24