DS-KIS701 Video Intercom Bundle Quick Start Guide
QSG DS-KIS701 Video Intercom Bundle 080519NA 12
Cable
CableCable
Cable
Resistance
Resistance Resistance
Resistance
per 100 m
per 100 mper 100 m
per 100 m
Maximum
MaximumMaximum
Maximum
Transmission
Transmission Transmission
Transmission
Distance
DistanceDistance
Distance
Max. Distance
Max. Distance Max. Distance
Max. Distance
(Door
(Door(Door
(Door
station doesn’t
station doesn’t station doesn’t
station doesn’t
electric lock
electric lockelectric lock
electric lock
Max. Distance
Max. Distance Max. Distance
Max. Distance
(Door station s
(Door station s(Door station s
(Door station supplies
upplies upplies
upplies
electric lock
electric lockelectric lock
electric lock
24 AWG 10 Ω 50 m 50 m 30 m
20 AWG 7 Ω 100 m 100 m 80 m
18 AWG 4 Ω 150 m 150 m 100 m
•
The input voltage for the electric lock is 12 V and the maximum current is 200 mA.
•
If using a network cable as the 24 AWG cable, use two conductors to connect to one device and
spare the other six.
Wire the three devices with power supply cables as in the picture shown below.
Figure 8, Wiring
•
It’s advised to connect only one video/audio distributor to one switch. If you need to connect
more than one video/audio distributor to the switch, please set the PLC channel.