35.2. APPENDIX B - Event/Alarm Logs
Events Logs are structured as follows:
Security Log
Event / Alert Code Meaning
Event /
Alert Code
Mandated /
Non-mandated
Alert
WAN
(Alert Type)
Alert
HAN
Clock not adjusted (adjustment greater than 10
seconds) or outside the validity period if via a set
clock command
0x8F0C
Mandated
Y (1)
N
Comms Hub Device Log Changed
0x8F12
Mandated
Y (2)
N
Firmware Verification Failed
0x8F1C
Mandated
Y (2)
N
Integrity check of content or format of command
failed
0x8F1E
Mandated
Y (1)
N
Unauthorised Communication Access attempted
0x8F3E
Mandated
Y (1)
N
Unauthorised Physical Access - Tamper Detect
0x8F3F
Mandated -
conditional
group 1
Y (1)
N
Change in the executing Firmware version
0x8F43
Mandated
N
N
Credit would cause Meter Balance to exceed
Maximum Meter Balance Threshold
0x8F47
Mandated
N
N
Device joining failed
0x8F48
Mandated
N
N
Device joining succeeded
0x8F49
Mandated
N
N
Device Unjoining failed
0x8F4A
Mandated
N
N
Device Unjoining succeeded
0x8F4B
Mandated
N
N
Device's own Digital Signing Certificate
replacement failed
0x8F4C
Mandated
N
N
Device's own Digital Signing Certificate
replacement succeeded
0x8F4D
Mandated
N
N
Device's own Key Agreement Certificate
replacement failed
0x8F4E
Mandated
N
N
Device's own Key Agreement Certificate
replacement succeeded
0x8F4F
Mandated
N
N
Duplicate UTRN entered
0x8F51
Mandated
N
N
Event Log Cleared
0x8F52
Mandated
N
N
Failed Authentication or Authorisation not covered
by other codes
0x8F53
Mandated
N
N
UTRN exceeds Maximum Credit Threshold
0x8F5B
Mandated
N
N
Unusual numbers of malformed, out-of-order or
unexpected Commands received
0x8F60
Mandated
N
N
UTRN not Authentic
0x8F63
Mandated
N
N
UTRN not for this Device
0x8F64
Mandated
N
N
Update Security Credentials
0x8F70
Mandated
N
N
Firmware Verification Successful
0x8F72
Mandated
Y (2)
N
Unauthorised Physical Access - Meter Cover
Removed
0x8F74
Mandated -
conditional
group 1
Y (1)
N

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell AS302P and is the answer not in the manual?

Honeywell AS302P Specifications

General IconGeneral
BrandHoneywell
ModelAS302P
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals