EasyManuals Logo
Home>Honeywell>Recording Equipment>CIU 888

Honeywell CIU 888 Firmware Upgrade Manual

Honeywell CIU 888
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
Firmware Upgrades
Part No.: 4417596_Rev11 Firmware Upgrade Manual
CIU 888 1 - 9
$*6
e) In the configure page, under CIU element, select “VPN Port” to
see the properties. It will have the default values.
f) Enter VPN configuration details and click Update. In case of a
redundant configuration, the partner IP address should also be
set via the active CIU. This data will be synced to partner. After
restarting, partner CIU VPN port will have partner IP address
assigned.
g) The CIU’s will get restart successfully after sending the changes.
h) After restarting, the CIU is accessible via VPN port.
15.If the CIU 888 includes the sealing option and is intended to be
sealed, have it sealed by a representative of the W&M authorities or
by a W&M accredited user. Refer to the Sealing Guide CIU 888 (Part
No. 4417595) for more information.
16.Verify that the system setup is working properly. Refer to
section 2.10 in the Configuration Manual CIU 888 (Part No.
4417584) for more information.
NOTE: Before migration, if ambient temperature was configured to be not scanned
and not manually over written, after migration, the ambient temperature value
is shown as 20 deg C. In this scenario please reset to the appropriate ambient
temperature value. After restart, verify the latest release and build version on
web.
1.5 Installing a firmware upgrade on a redundant system setup
In case of a fully commissioned redundant system setup, a firmware
upgrade must be installed on both the primary CIU 888 and the
secondary CIU 888.
REMARKS: 1. In the following procedure, it is assumed that the primary CIU 888 normally
has the active role and the secondary CIU 888 the passive role.
2. The primary CIU 888 and the secondary CIU 888 must be fully
synchronized before installing a firmware upgrade.
The installation of a firmware upgrade may be irreversible! Therefore, ensure that the correct
firmware is selected for the firmware upgrade.

Other manuals for Honeywell CIU 888

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell CIU 888 and is the answer not in the manual?

Honeywell CIU 888 Specifications

General IconGeneral
BrandHoneywell
ModelCIU 888
CategoryRecording Equipment
LanguageEnglish

Related product manuals