55 Enabling the 5842 Wireless Dialer
This is an interactive menu mode that is used to enable and program the 5842 Wireless Dialer. When enabled, the
5842 will serve as the primary dialer. The 5842 Wireless Dialer combines the functions of a Central Station dialer
and an RF transceiver. It interfaces with the Lynx control via the built in transceiver. The 5842 receives and
acknowledges RF messages from the controls transceiver and, in response, sends reports to the central station via
the dialer. The 5842 also sends acknowledgements, supervisory and tamper RF transmissions to the control. If the
wireless dialer has tried unsuccessfully 8 or 16 times (dependent on the number of phone numbers programmed) to
send a report, the Lynx will attempt to report to the Central Station via the on-board dialer (if it has been
programmed for back-up reporting). The Back-up reporting option must be selected for Follow-me, Pager and AAV
operation (refer to field *49).
/<1; PXVW EH FRQQHFWHG WR WKH WHOHSKRQH OLQH LI XVLQJ WKH %DFNXS UHSRUWLQJ RSWLRQ
Wireless Dialer Setup
If the wireless dialer is enabled in Field
55, Lynx automatically sends the setup information to the wireless dialer
immediately after exiting the programming mode. Lynx will confirm that the 5842 wireless dialer has successfully
received the setup information by generating three beeps. If the setup information has not been successfully
received by the wireless dialer the Lynx will generate a single beep once per minute and Fault Zone 93 will be
displayed. To prepare the dialer for setup refer to the Installation Instructions provided with the 5842 Wireless
Dialer.
Note:
1. It takes about95 seconds for Lynx to transmit the setup information after power has been applied to the control.
2. Entering Programming mode may take up to three (3) seconds if the 5842 Wireless Dialer has been enabled.
You must refer to these instructions or to the Programming Guide while programming the system because the keypad display does not
show prompt titles. Instead, prompts are indicated by a number/letter combination.
The prompts for
55 are as follows:
Ed Enable Dialer------------------------------------ for enabling the 5482 wireless dialer
Er Enable Trouble/Supervisory Reports----- for defining wireless dialer response to events*
Ln Response to Phone Line Failure ----------- for defining phone system response to phone line cut
Eb Enable Back-up Reporting ------------------ for enabling the backup dialer
*The Contact ID® Event Codes for the reports associated with the 5842 wireless dialer include the following:
145 Wireless Dialer Tamper (Alarm)
338 Wireless Dialer Low Battery
341 Wireless Dialer Tamper (Trouble)
342 Wireless Dialer AC Loss (if supported by the 5842 Wireless Dialer being installed)
351 Wireless Dialer Phone Line Cut (if supported by the 5842 Wireless Dialer being installed)
355 Wireless Dialer Loss of RF Supervision
For additional information refer to the Contact ID® Event Codes table.

Other manuals for Honeywell LYNXR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell LYNXR and is the answer not in the manual?

Honeywell LYNXR Specifications

General IconGeneral
BrandHoneywell
ModelLYNXR
CategorySecurity System
LanguageEnglish

Related product manuals