Procedure
Step 1 Based on the cross-sectional area of the cable conductor, strip a length of insulation coating C
to expose the conductor D of length L1, as shown in Figure 5-2. The recommended values of
L1 are listed in Table 5-1.
Figure 5-2 Stripping a power cable (OT terminal)
NOTICE
l When you strip a power cable, do not damage the conductor of the cable.
l If the bare crimping terminal is not provided by Huawei, the value of L1 is 1 mm (0.04 in.)
to 2 mm (0.08 in.) greater than the value of L.
Table 5-1 Mapping between the cross-sectional area of the conductor and the value of L1
Cross-
Sectional Area
of Conductor
(mm
2
(in.
2
))
Value of L1 (mm
(in.))
Cross-Sectional
Area of Conductor
(mm
2
(in.
2
))
Value of L1 (mm
(in.))
1 (0.002) 7 (0.28) 10 (0.015) 11 (0.43)
1.5 (0.002) 7 (0.28) 16 (0.025) 13 (0.51)
2.5 (0.004) 7 (0.28) 25 (0.039) 14 (0.55)
4 (0.006) 8 (0.31) 35 (0.054) 16 (0.63)
6 (0.009) 9 (0.35) 50 (0.077) 16 (0.63)
Huawei AP3x10xN&5x10xN&5x30xN&6x10xN&7x10xN
Hardware Installation and Maintenance Guide
5 Appendix
Issue 11 (2015-05-18) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
40

Other manuals for Huawei AP5030DN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei AP5030DN and is the answer not in the manual?

Huawei AP5030DN Specifications

General IconGeneral
BrandHuawei
ModelAP5030DN
CategoryWireless Access Point
LanguageEnglish

Related product manuals