50 Husqvarna service manual 104 72 30-26
Feeding guide compl. (step motor)
Dismounting
Turn off the main switch.
Remove the rear cover.
Remove the screws for the cable groove.
Remove the cable of the step motor from the circuit board.
Note the position of the nut (A) on the screw and remove it.
Remove the screws (B).
The feeding guide can now be removed.
Mounting
Fit the block (C) into the guide (D) (see illustration).
Push aside the stitch regulator fork (E).
Mount the feeding guide into the machine and thread the stud of the fork into the hole of the
block.
Tighten the screws (B).
Tighten the nuts (A).
Connect the cables to the circuit board.
Mount the cable groove.
Thereafter set:
The stitch length balance (P.36-40).