58 – English
TROUBLESHOOTING
C1D0315 Blade clutch
Circuit short to
battery or open
Blade clutch can not be
controlled by the HMI. Blade
might be engaged or
disengaged the whole time.
Check blade clutch in relay/fuse box.
Check damage to HMI connector, harness to relay/fuse box
and relay/fuse box connector. If found, repair and restart
system, reset fault code.
If problem still exists, contact your service agent for further
information.
C1D0311 Blade clutch
Circuit short to
ground
Blade clutch can not be
controlled by the HMI. Blade
might be engaged or
disengaged the whole time.
Check blade clutch in relay/fuse box.
Check damage to HMI connector, harness to relay/fuse box
and relay/fuse box connector. If found, repair and restart
system, reset fault code.
If problem still exists, contact your service agent for further
information.
C1D0615 Water pump
Circuit short to
battery or open
Water pump can not be
controlled by the HMI. May
not be able to turn on.
Check water pump relay in relay/fuse box.
Check damage to HMI connector, harness to relay/fuse box
and relay/fuse box connector. If found, repair and restart
system, reset fault code.
If problem still exists, contact your service agent for further
information.
C1D0611 Water pump
Circuit short to
ground
Water pump can not be
turned on.
Check water pump relay in relay/fuse box.
Check damage to HMI connector, harness to relay/fuse box
and relay/fuse box connector. If found, repair and restart
system, reset fault code.
If problem still exists, contact your service agent for further
information.
C1D0915 Working light
Circuit short to
battery or open
Check working light relay in
relay/fuse box.
Working light can not be controlled by the HMI. May not be
able to turn on.
Check damage to HMI connector, harness to relay/fuse box
and relay/fuse box connector. If found, repair and restart
system, reset fault code.
If problem still exists, contact your service agent for further
information.
C1D0911 Working light
Circuit short to
ground
Check working light relay in
relay/fuse box.
Working light can not be turned on.
Check damage to HMI connector, harness to relay/fuse box
and relay/fuse box connector. If found, repair and restart
system, reset fault code.
If problem still exists, contact your service agent for further
information.
C1D0C15 Ignition
Circuit short to
battery or open
Engine can not be started.
Yanmar:
Check fuel pump relay in relay/fuse box.
Check damage to HMI connector, harness to relay/fuse box
and relay/fuse box connector. If found, repair and restart
system, reset fault code.
If problem still exists, contact your service agent for further
information.
Deutz:
Check damage to HMI and ECU connector and harness. If
found, repair and restart system, reset fault code.
If problem still exists, contact your service agent for further
information.
C1D0C11 Ignition
Circuit short to
ground
Engine can not be started.
Yanmar:
Check fuel pump relay in relay/fuse box.
Check damage to HMI connector, harness to relay/fuse box
and relay/fuse box connector. If found, repair and restart
system, reset fault code.
If problem still exists, contact your service agent for further
information.
Deutz:
Check damage to HMI and ECU connector and harness. If
found, repair and restart system, reset fault code.
If problem still exists, contact your service agent for further
information.
C1D0D15
Hydraulic lift
pump
Circuit short to
battery or open
Hydraulic lift pump can’t be
used for raising the blade.
Check relay in relay/fuse box.
Check damage to HMI connector, harness to relay/fuse box
and relay/fuse box connector. If found, repair and restart
system, reset fault code.
If problem still exists, contact your service agent for further
information.