TROUBLESHOOTING
Error messages
Fault Code
Message on the
display
DTC description Indication on the machine Possible action
U100087 I/O Controller
No CAN
communication
Engine can not be started. No
machine function can be
controlled.
Check damage to HMI connector and chassis harness. If
found, repair and restart system, reset fault code.
If problem still exists, contact your service agent for further
information.
U100088 I/O Controller
Software download
failed
Engine can not be started. No
machine function can be
controlled.
Contact your service agent.
P060745 IOC MPU
Program memory
failure
Engine can not be started. No
machine function can be
controlled.
Contact your service agent for further information.
P060742 IOC MPU
General memory
failure
Engine can not be started. No
machine function can be
controlled.
Contact your service agent for further information.
C1E0111
Blade depth
sensor signal
Circuit short to
ground
Blade depth can not be
displayed. Blade depth stop
can not be used.
Disconnect sensor and reset fault code. If fault code no longer
exists check sensor and sensor harness.
Check damage to HMI connectors and harness to sensors. If
found, repair and restart system, reset fault codes.
Contact your service agent for further information.
C1E0112
Blade depth
sensor signal
Circuit short to
battery
Blade depth can not be
displayed. Blade depth stop
can not be used.
Disconnect sensor and reset fault code. If fault code no longer
exists check sensor and sensor harness.
Check damage to HMI connectors and harness to sensors. If
found, repair and restart system, reset fault codes.
Contact your service agent for further information.
C1D0115 Starter
Circuit short to
battery or open
Engine starter can not be
controlled. Cutting can not
continue.
Check damage to HMI and ECU connector and harness. If
found, repair and restart system, reset fault code.
It problem still exists, contact your service agent for further
information.
C1D0111 Starter
Circuit short to
ground
Engine can not be started.
Check damage to HMI and ECU connector and harness. If
found, repair and restart system, reset fault code.
If problem still exists, contact your service agent for further
information.
C1D0711
Power supply
external device
Circuit short to
ground
Cutting can not continue.
Check cables to:
Blade depth sensor and sensor itself
E-track position sensor and sensor itself
Neutral start switch and switch itself
Fuel level sensor and sensor itself
Lower/raise switch and switch itself
Water safety switch and switch itself
Change HMI
C1D0815 AUX1
Circuit short to
battery or open
AUX1 can not be controlled by
the HMI.
Check AUX1 relay in relay/fuse box.
Check damage to HMI connector, harness to relay/fuse box
and relay/fuse box connector. If found, repair and restart
system, reset fault code.
If problem still exists, contact your service agent for further
information.
C1D0811 AUX1
Circuit short to
ground
AUX1 can not be controlled by
the HMI.
Check AUX1 relay in relay/fuse box.
Check damage to HMI connector, harness to relay/fuse box
and relay/fuse box connector. If found, repair and restart
system, reset fault code.
If problem still exists, contact your service agent for further
information.
C1D0215 AUX2
Circuit short to
battery or open
AUX2 can not be controlled by
the HMI.
Check AUX2 relay in relay/fuse box.
Check damage to HMI connector, harness to relay/fuse box
and relay/fuse box connector. If found, repair and restart
system, reset fault code.
If problem still exists, contact your service agent for further
information.
C1D0211 AUX2
Circuit short to
ground
AUX2 can not be controlled by
the HMI.
Check AUX2 relay in relay/fuse box.
Check damage to HMI connector, harness to relay/fuse box
and relay/fuse box connector. If found, repair and restart
system, reset fault code.
If problem still exists, contact your service agent for further
information.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Husqvarna FS5000 D and is the answer not in the manual?

Husqvarna FS5000 D Specifications

General IconGeneral
BrandHusqvarna
ModelFS5000 D
CategorySaw
LanguageEnglish

Related product manuals