MAINTENANCE
5-30 HT4400 Instruction Manual
3
Chopper
Plasma Power Supply
Start Circuit
Choke
Control
Logic
IGBT
Power Resistor
ALEL Caps
Diode
Cutting
Arc
Pilot
Arc
Start Circuit Functional Schematic
Start Circuit Troubleshooting
D2 should always be ON.
D1 illuminates as soon as the torch fires and then will extinguish as soon as the arc transfers to the plate. If
arc transfer is immediate, the LED will not illuminate.
If there is no arc at the torch or if the arc will not transfer:
Turn the power to the system OFF and check for a resistance of 15 k from H8 to H1.
Check for a resistance of 5.5 k across H10 and H4.
Refer to wiring diagrams. Note that the resistances will slowly increase to the above values due to
capacitance in the circuit.
Check the junction of the D12 diode.
Work cable connection on the cutting table is not making good contact.
Check D2. It should be illuminated.
Fire the torch in the air and check to be sure that D1 illuminates.
Check the resistance across the R3 resistor. It should be 10 k.
WARNING
SHOCK HAZARD: Always use caution when servicing a power supply when plugged in and the
covers are removed. Dangerous voltages exist within the power supply which could cause injury
or death.