INSTALLATION
3-14 HT4400 Instruction Manual
Ignition Console Connections – 3 of 3
Cable - Ignition Console to Valve Cluster
Torch Leads
Installation Notes
RUN LIST – Ignition Console to
Valve Cluster Cable
Note: 2X2 and 4X1 are not labeled on the
cable. Plug one cable end into the 2X2 Ignition
Console receptacle and the other cable end
into the Valve Cluster cable receptacle.
SIGNAL 2X2 COLOR 4X1
SV8 7 White 1
SV8 20 Yellow 2
SV9 8 White 4
SV9 21 Orange 5
SV10 9 White 7
SV10 22 Brown 8
SV11 10 White 10
SV11 23 Black 11
SV12 11 White 13
SV12 24 Red 14
PE (Gnd) 6 White 12
PE (Gnd) 12 Green 3
See also Torch Connections, Mounting
and Alignment later in this section.
Part No. Length
123509 6 ft (1.8 m)
123510 10 ft (3 m)
Part No. Length
123511 15 ft (4.6 m)
Part No. Length
128462 6 ft (1.8 m)
128463 10 ft (3 m)
128341 15 ft (4.6 m)
2X2 4X1