MAINTENANCE
5-6 HPR260 Manual Gas Instruction Manual
4
Gas system purge cycle
When the system is turned on, or the operator changes from one process to another, the system automatically goes
through a purge process. The purge process has 2 stages; a preflow purge and a cutflow purge.
The preflow gas is turned on for 8 seconds with an auto gas console, or 12 seconds with a manual gas console.
The cutflow gas is turned on for 8 seconds with an auto gas console, or 12 seconds with a manual gas console.
There are 2 exceptions to the process described above.
Exception 1 if the operator changes from a non-fuel gas process (O
2
/Air, Air/Air, or N
2
/Air) to a fuel fuel gas process
(H35/N
2
, or F5/N
2
) or the reverse, there will be 3 stages to the purge process. Nitrogen will purge the
gas system first, for 12 seconds. The preflow and cutflow purges will follow the nitrogen purge.
Note: error code 42 (low nitrogen gas pressure) will be displayed, if nitrogen is not connected to the gas system. If
error code 42 is not resolved in 3 minutes, it will be replaced by error code 139 (purge time-out error).
Exception 2 no purge process will occur if the operator changes from any process to a nitrogen marking process.
Gas system valve usage
The following tables show which valves are active for each cutting process.
O
2
/O
2
process
Gas console AC valve driver board LEDs
Valve
location
Gas console Off-valve
LED
number
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Preflow
SV1 SV2 SV4 SV7 SV10 SV17 SV18
Cutflow
SV1 SV2 SV4 SV7 SV10 SV14 SV16 SV19
O
2
/Air
process
Gas console AC valve driver board LEDs
Valve
location
Gas console Off-valve
LED
number
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Preflow
SV1 SV2 SV5 SV7 SV10 SV17 SV18
Cutflow
SV1 SV2 SV5 SV7 SV10 SV14 SV16 SV19

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR260 and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR260 Specifications

General IconGeneral
BrandHypertherm
ModelHyPerformance Plasma HPR260
CategoryCutter
LanguageEnglish

Related product manuals