EasyManuals Logo
Home>Hypertherm>Cutter>HyPerformance Plasma HPR260

Hypertherm HyPerformance Plasma HPR260 User Manual

Hypertherm HyPerformance Plasma HPR260
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #175 background imageLoading...
Page #175 background image
MAINTENANCE
HPR260 Manual Gas Instruction Manual 5-41
4
Pilot arc current levels
The pilot arc current level will change depending on the chosen process and arc current level. See table below.
Pilot arc current
Plasma gas 30-amps 45-amps 50-amps 80-amps 130-amps 200-amps 260-amps
O
2
25 30 30 30 30 40 40
N
2
25 30 30 30 35 40 40
H35 25 30 30 30 35 40 40
F5 25 30 30 30 35 40 40
Air 25 30 30 30 35 40 40
Transfer current
Plasma gas 30-amps 45-amps 50-amps 80-amps 130-amps 200-amps 260-amps
O
2
10 10 10 10 15 20 20
N
2
10 10 10 10 15 20 20
H35 10 10 10 10 15 20 20
F5 10 10 10 10 15 20 20
Air 10 10 10 10 15 20 20

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR260 and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR260 Specifications

General IconGeneral
BrandHypertherm
ModelHyPerformance Plasma HPR260
CategoryCutter
LanguageEnglish

Related product manuals