HyPrecision Predictive waterjet pump Operator Manual 810120 131
5 – Preventive maintenance
Preventive maintenance
5. Touch the applicable symbol on the screen to record the reason that the part was replaced. This
information is saved as a .CSV file on the SD card.
6. If maintenance is done on both ends of the intensifier, do these steps again for the other
high-pressure end.
7. Touch the bottom repair symbol on the Record Maintenance screen to open the Pump Components
screen.
There is 1 Pump Components screen.
8. Touch the symbol on the screen for the part that was replaced.
After a symbol is selected, the Maintenance Reason screen opens.
1
Leak
2
Worn or broken part
3
Scheduled preventive maintenance
1
Water filter cartridges
1-15470 (0.22 micron)
1-11106 (1.0 micron)
1-11107 (10 micron)
1,000 hours
2
Hydraulic filter
1-16025
1,500 hours
3
Seal Maintenance Indicator tubes
replacement kit
1-17483
2,000 hours
4
Bleed-down valve repair kit
1-17434
1,000 hours
5
Hydraulic fluid service kit
1-17473
3,000 hours
6
Bleed-down valve body
1-14141
3,000 hour